![Mitsubishi Electric A173UHCPU Скачать руководство пользователя страница 202](http://html.mh-extra.com/html/mitsubishi-electric/a173uhcpu/a173uhcpu_programming-manual_238567202.webp)
7. POSITIONING CONTROL
7
−
55
POINT
(1) Do not set the travel value to zero for fixed-pitch feed control.
The following results if the travel value is set to zero:
(a) If both axes are set to zero, the fixed-pitch feed ends with no feed
taking place.
(b) If the travel value is set to zero for one axis only, fixed-pitch feed
control will not occur at the normal positioning speed for the axis set
to a non-zero travel value.
[Program Example]
This program conducts fixed-pitch feed control using 2-axes linear interpolation
under the conditions below.
(1) System configuration
Fixed-pitch feed control using 2-axes linear interpolation of Axis 2 and Axis 3.
M
M
M
M
A61P A273UH
CPU
A278
LX
Axis
1
Axis
2
Axis
3
Axis
4
A61P AX41
Start command (X000)
MR- -B MR- -B MR- -B MR- -B
(2) Positioning conditions
The fixed-pitch feed control conditions are shown below.
Item
Setting
Servo program number
No. 310
Positioning speed
10000
Controlled axis
Axis 2
Axis 3
Travel value
500000
300000
(a) Fixed-pitch feed control start command ....... leading edge of X000
(OFF
→
ON)