7. POSITIONING CONTROL
7
−
12
3) Immediate stop ...........
(Process 3)
Stops without deceleration processing.
Stop cause
Stop
(b) Order of priority for stops
The order of priority for stops when a stop cause is input is as follows:
Process 1 < Process 2 <Process 3
A rapid stop (Process 2) is started if a rapid stop cause is input during one of the
following types of deceleration stop processing:
•
after automatic deceleration starts during positioning control;
•
during deceleration after JOG start signal turns OFF;
•
during deceleration stop processing due to a stop cause (Process 1).
Deceleration stop processing
Rapid stop cause
Rapid stop deceleration
processing
Stop
Example