APPENDICES
APP
−
30
Table 2.14 Servo Amplifier Error List (2000 to 2799) (Continued)
Error Cause
Error
Code
Amplifier
Type
Name
Description
When Error Checked
Error Processing
Corrective Action
•
The servo parameter value is outside
the setting range. (Any unauthorized
parameter is ignored and the value
before setting is retained.)
2301
Amplifier setting
2302
Motor type
2303
Motor capacity
2304
Number of feedback
pulses
2305
In-position range
2306
Position control gain 2
(actual position gain)
2307
Speed control gain 2
(actual speed gain)
2308
Speed integral
compensation
2309
Forward rotation torque
limit value
2310
Reverse rotation torque
limit value
2311
Emergency stop time
delay
2312
Position control gain 1
(model position gain)
2313
Speed control gain 1
(model speed gain)
2314
Load inertia ratio
2315
Error excessive alarm
level
2316
Special compensation
processing
2317
Special servo
processing
2318
Td dead zone
compensation
2319
Feed forward gain
2320
Unbalance torque
compensation
2321
Dither command
2322
Gain operation time
2323
Servo response level
setting
2324
2301
to
2324
A
Parameter
alarm
At any time during operation
•
Check the setting ranges of the servo
parameters.
2500
A
Parameter
alarm
•
Among the servo parameters, any
of the following items is
unauthorized.
•
Amplifier
•
External regenerative brake
resistor setting
•
Motor type
•
Motor capacity
•
At power-on of servo
amplifier
•
At servo error reset
Operation
continues
•
Reconsider the system settings and
servo parameters.