![Mitsubishi Electric A173UHCPU Скачать руководство пользователя страница 216](http://html.mh-extra.com/html/mitsubishi-electric/a173uhcpu/a173uhcpu_programming-manual_238567216.webp)
7. POSITIONING CONTROL
7
−
69
POINT
If control is started by turning M3212+20n ON, leave M3212+20n ON until
positioning control is completed.
The feed current value cannot be guaranteed if M3212+20n is turned OFF
during control.
(4) Changing travel value during speed control
After speed/position switching control is started, the travel value for position
control can be changed while speed control is in progress. Follow the
procedure described below to change the travel value.
(a) Indirectly designate the travel value in the servo program using the 2-word
data registers shown in the table below.
Data Registers to Change Travel Value
Axis No.
Data Register Number
for Indirect
Designation
Most-Significant Data
Least-Significant Data
1
D16
D17
D16
2
D36
D37
D36
3
D56
D57
D56
4
D76
D77
D76
5
D96
D97
D96
6
D116
D117
D116
7
D136
D137
D136
8
D156
D157
D156
9
D176
D177
D176
10
D196
D197
D196
11
D216
D217
D216
12
D236
D237
D236
13
D256
D257
D256
14
D276
D277
D276
15
D296
D297
D296
16
D316
D317
D316
17
D336
D337
D336
18
D356
D357
D356
19
D376
D377
D376
20
D396
D397
D396
21
D416
D417
D416
22
D436
D437
D436
23
D456
D457
D456
24
D476
D477
D476
25
D496
D497
D496
26
D516
D517
D516
27
D536
D537
D536
28
D556
D557
D556
29
D576
D577
D576
30
D596
D597
D596
31
D616
D617
D616
32
D636
D637
D636