APPENDICES
APP
−
50
Table 3.2 Special Register List (Continued)
Number
Name
Stored Data
Explanation
D752
Manual pulse
generator 1 (P1)
smoothing
magnification
setting area
D753
Manual pulse
generator 2 (P2)
smoothing
magnification
setting area
D754
Manual pulse
generator 3 (P3)
smoothing
magnification
setting area
Manual pulse generator smoothing
magnification setting area
!
Stores the smoothing time constant of the manual pulse generator.
!
The smoothing time constant is calculated by the following expression.
Smoothing time constant (t) = (smoothing magnifi 1)
×
56.8 [ms]
Note that the setting range of the smoothing magnification is 0 to 59.
D776
to
D791
Axis 1 to 32 limit
switch output
status storing
area
Limit switch output status storing
area
1 : ON
0 : OFF
!
Stores 1 or 0 to indicate the output status (ON/OFF) to the limit switch output
AY42 set on the peripheral device.
1 : ON
0 : OFF
!
May be used to export the limit switch output data in a sequence program.
b15
b14
b13
b12
b11
b10
b9
b8
b7
b6
b5
b4
b3
b2
b1
b0
LY0F LY0E LY0D LY0C LY0B LY0A LY09 LY08 LY07 LY06 LY05 LY04 LY03 LY02 LY01 LY00
D776
LY1F LY1E LY1D LY1C LY1B LY1A LY19 LY18 LY17 LY16 LY15 LY14 LY13 LY12 LY11 LY10
D777
b15
b14
b13
b12
b11
b10
b9
b8
b7
b6
b5
b4
b3
b2
b1
b0
LYEF LYEE LYED LYEC LYEB LYEA LYE9 LYE8 LYE7 LYE6 LYE5 LYE4 LYE3 LYE2 LYE1 LYE0
D790
LYFF LYFE LYFD LYFC LYFB LYFA LYF9 LYF8 LYF7 LYF6 LYF5 LYF4 LYF3 LYF2 LYF1 LYF0
D791
For axis 2
For axis 4
For axis 1
For axis 3
For axis 30
For axis 32
For axis 29
For axis 31
Each bit of D776 to D791 stores 1/0.
1) 1 : ON
2) 0 : OFF
D792
to
D799
Servo amplifier
type
Servo amplifier type
!
Stores the servo amplifier type specified in the system settings at power-on or
rest.
D799
b15 to b12 b11 to b8
b7 to b4
b3 to b0
D798
D797
D796
D795
D794
D793
D792
Axis 1
Axis 5
Axis 9
Axis 13
Axis 17
Axis 21
Axis 25
Axis 29
Axis 2
Axis 6
Axis 10
Axis 14
Axis 18
Axis 22
Axis 26
Axis 30
Axis 3
Axis 7
Axis 11
Axis 15
Axis 19
Axis 23
Axis 27
Axis 31
Axis 4
Axis 8
Axis 12
Axis 16
Axis 20
Axis 24
Axis 28
Axis 32
Servo amplifier type
0 ..... Unused axis
1 ..... ADU (CPU base)
2 ..... MR- -B
5 ..... ADU (motion extension base)
D9182
to
D9183
Test mode
request error
Test mode request error
!
Stores the starting axis data when the test mode request error flag (M9078) turns
ON.
D9183
b15 b14 b13 b12 b11 b10
b9
b8
b7
b4
b3
b2
b1
b0
b6
b5
D9182
Axis 1
Axis 2
Axis 3
Axis 4
Axis 5
Axis 6
Axis 7
Axis 8
Axis 9
Axis 10
Axis 11
Axis 12
Axis 13
Axis 14
Axis 15
Axis 16
Axis 17
Axis 18
Axis 19
Axis 20
Axis 21
Axis 22
Axis 23
Axis 24
Axis 25
Axis 26
Axis 27
Axis 28
Axis 29
Axis 30
Axis 31
Axis 32
Stores starting/stopping state of each axis.
0: Stopping
1: Starting