![Mitsubishi Electric A173UHCPU Скачать руководство пользователя страница 248](http://html.mh-extra.com/html/mitsubishi-electric/a173uhcpu/a173uhcpu_programming-manual_238567248.webp)
7. POSITIONING CONTROL
7
−
101
[Program Example]
This program turns ON M2040 during constant-speed control instruction execution
and changes the speed, under the conditions below.
(1) System configuration
Switches speed for Axis 1 and Axis 2.
Axis
2
A61P A273UH
CPU
A278
LX
M
Axis
1
M
M
M
A61P AX41
Start command(X000)
MR- -B MR- -B MR- -B MR- -B
Axis
3
Axis
4
(2) Positioning conditions
(a) The speed switching conditions are shown below.
Item
Setting
Servo program
number
310
Positioning speed
10000
Positioning method
2-axes linear
interpolation
Circular interpolation
using center point
designation
2-axes linear
interpolation
2-axes linear
interpolation
Axis 1
20000
30000
40000
50000
Pass point
Axis 2
10000
20000
25000
40000
(b) Constant-speed control with speed switching start command ....... leading
edge of X000 (OFF
→
ON)