![Mitsubishi Electric A173UHCPU Скачать руководство пользователя страница 142](http://html.mh-extra.com/html/mitsubishi-electric/a173uhcpu/a173uhcpu_programming-manual_238567142.webp)
6. SERVO PROGRAMS FOR POSITIONING CONTROL
6
−
12
Settings Made Using the Sequence Program (Indirect Setting)
Indirect Setting
Processing in Event of Setting Error
Setting Range
mm
inch
degree
PULSE
Possible/Not
Possible
Number of
Words Used
Error Item Data(note-4)
(Stored in D9190)
Control Using
Default Value
Starting not
Possible
0
1
2
3
"
1
11
1 to 600000000
(
×
10
−
2
mm/min)
1 to 600000000
(
×
10
−
3
inch/min)
1 to 2147483647
(
×
10
−
3
degree/min)
1 to 10000000
(PLS/s)
"
2
12
1 to 65535 (ms)
"
1
13
1 to 65535 (ms)
"
1
14
1 to 65535 (ms)
"
1
15
1 to 100 (%)
"
2
21
1 to 500 (%)
"
1
16
0: Deceleration to a stop in accordance with the deceleration time
1: Deceleration to a stop in accordance with the rapid stop deceleration time
"
1
0 to 100000
"
2
17
"
1 to 32767
"
18
Controlled by K1
0 to 4095
"
19
"
1 to 600000000
(
×
10
−
2
mm/min)
1 to 600000000
(
×
10
−
3
inch/min)
1 to 2147483647
(
×
10
−
3
degree/min)
1 to 10000000
(PLS/s)
"
2
4
"
(Note-2)
"
(Note-3)
0 to 4095
"
1
1 to 5000 (ms)
"
1
13
"
REMARKS
(Note-2) : When an error occurs because the speed limit value is exceeded,
control is executed at the speed limit value.
(Note-3) : Applies when the commanded speed is "0".
(Note-4) : If there are multiple errors in the same program, the latest error item
data is stored.