![Mitsubishi Electric A173UHCPU Скачать руководство пользователя страница 172](http://html.mh-extra.com/html/mitsubishi-electric/a173uhcpu/a173uhcpu_programming-manual_238567172.webp)
7. POSITIONING CONTROL
7
−
25
[Program Example]
This program conducts 2-axes linear interpolation control under the conditions
below.
(1) System configuration
2-axes linear interpolation control of Axis 3 and Axis 4.
M
M
M
M
A61P A273UH
CPU
A278
LX
Axis
1
Axis
2
Axis
3
Axis
4
A61P AX41
Positioning start command (X000)
MR- -B MR- -B MR- -B MR- -B
(2) Positioning details
The positioning by the Axis 3 and Axis 4 servo motors is shown in the diagram
below.
Positioning by No. 11
servo program
(40000, 50000)
Axis 4 positioning
direction
Home position
(0, 0)
Axis 3 positioning
direction
(3) Positioning conditions
(a) The positioning conditions are shown below.
Servo Program Number
Item
No. 11
Positioning speed
30000
(b) Positioning start ........... leading edge of X000 (OFF
→
ON)