![Mitsubishi Electric A173UHCPU Скачать руководство пользователя страница 213](http://html.mh-extra.com/html/mitsubishi-electric/a173uhcpu/a173uhcpu_programming-manual_238567213.webp)
7. POSITIONING CONTROL
7
−
66
(4) Servo program
The servo program No. 55 for speed control (II) is shown below.
Speed control (I) (Forward)
Axis used Axis 1
Positioning speed
3000
<K
91>
VF
Axis
1,
Speed
3000
(5) Sequence program
The sequence program which runs the servo program is shown below.
0
CIRCUIT END
M2000
SVST
2
4
14
16
M9039
M9074
X000
M55
M9074
M9074
M57
M2049 M9076
M2042
PLS
SET
RST
M55
M57
M57
55
K
J3
PLF M58
M2003
27
M58
SET M3240
29
M2003
RST M3240
M3240
Turns ON PLC ready.
Turns ON all axes servo start
command.
Servo program No.55 execution
request.
Turns OFF M57 on completion
of sarvo program No.55 execution
request.
Detects leading edge of X000
(OFF ON)
Detects leading edge of X000
(ON OFF)
Turns ON servo program No.55
start command flag (M57) when
X000 turns OFF ON.
Turns ON stop command flag
(M3240) at trailing edge of X000.
Turns OFF stop command flag
(M3240) when Axis 1 stops.