3. POSITIONING SIGNALS
3
−
7
3.1.1 Axis
status
(1) Positioning start completed signal (M2400+20n)
(a) This signal comes ON when starting of positioning control of the axis
designated by the SVST instruction in the sequence program is completed.
It does not come ON when positioning control starts due to a zeroing, JOG
operation or manual pulse generator operation.
It can be used, for example, to read an M-code when positioning is started.
(See Section 8.2.)
(b) The positioning start completed signal goes OFF at the leading edge
(OFF
→
ON) of the end signal OFF command (M3204+20n) or when
positioning is completed.
At the leading edge (OFF
→
→
→
→
ON) of the end signal OFF command
(M1804+20n)
Dwell time
t
ON
OFF
ON
ON
OFF
OFF
V
Start reception flag (M2001+n)
(Note-1)
SVST instruction
Positioning start completed
signal (M1600+20n)
End signal OFF command
(M3204+20n)
(Note-1)
(Note-1)
When positioning is completed
Dwell time
t
ON
OFF
ON
OFF
V
(Note-1)
Positioning start completed
signal (M2400+20n)
Start reception flag (M2001+n)
SVST instruction
Positioning
completed
(Note-1)
REMARK
(Note-1):In the preceding descriptions, "n" in M2001+n, M3204+20n, etc.
indicates a value for each axis No. in the following tables.
Axis No.
n
Axis No.
n
Axis No.
n
Axis No.
n
1
0
9
8
17
16
25
24
2
1
10
9
18
17
26
25
3
2
11
10
19
18
27
26
4
3
12
11
20
19
28
27
5
4
13
12
21
20
29
28
6
5
14
13
22
21
30
29
7
6
15
14
23
22
31
30
8
7
16
15
24
23
32
31
Make the following calculation to find the device number corresponding to
each axis.
(Example) M3200+20n (stop command) = M3200+20
×
31=M3820
M3215+20n (servo off)
= M3215+20
×
31=M3835