2AR
1-3-25
Correcting the toner sensor control voltage
The toner sensor control voltage is corrected based on the absolute humidity and the
total drive motor time so that the toner density is kept constant regardless of the
changes in humidity and the total drive motor time.
Toner sensor control voltage after correction = A + B + C
A: Toner sensor control voltage before correction (value set by maintenance item 131)
B: Correction data based on the absolute humidity
C: Correction data based on the total drive motor time
• Correction based on the absolute humidity
+
10
0
–
25
–
35
0
Correction data
2.0
4.0
10.0
20.0
32.0
Absolute humidity (g/m
3
)
A
B
C
D
E
Figure 1-3-21 Correction based on the absolute humidity
A
When the absolute humidity is between 0 and 2.0 g/m
3
, a constant value of
+
10 is
added to the toner sensor control voltage.
B
When the absolute humidity is between 2.0 and 4.0 g/m
3
, the correction data is
reduced according to the rise in absolute humidity.
C
When the absolute humidity is between 4.0 and 10.0 g/m
3
, the correction data
becomes 0.
D
When the absolute humidity is between 10.0 and 32.0 g/m
3
, the correction data is
decreased according to the rise in absolute humidity, reducing the toner sensor
control voltage.
E
When the absolute humidity exceeds 32.0 g/m
3
, the correction data becomes a
constant value of
–
35, decreasing the toner sensor control voltage.
Содержание PointSource Ai 3010
Страница 1: ...3010 S M MCA SERVICE MANUAL Published in Apr 00 2AR70765 Revision 5 PointSource Ai 3010 R...
Страница 2: ...Service Manual PointSource Ai 3010...
Страница 13: ...3010 S M MCA THEORY AND CONSTRUCTION SECTION I I Theory and Construction Section...
Страница 14: ...2AR CONTENTS 1 1 Specifications 1 1 1 Specifications 1 1 1...
Страница 18: ...2AR CONTENTS 1 2 Handling Precautions 1 2 1 Drum 1 2 1 1 2 2 Developer and toner 1 2 1...
Страница 61: ...3010 S M MCA ELECTRICAL SECTION II II Electrical Section...
Страница 62: ...2AR CONTENTS 2 1 Electrical Parts Layout 2 1 1 Electrical parts layout 2 1 1 1 Copier 2 1 1...
Страница 92: ...3010 S M MCA III Set Up and Adjustment Section III SET UP AND ADJUSTMENT SECTION...
Страница 108: ...3 1 15 2AR This page has been left blank intentionally 2AR 5...
Страница 136: ...3 2 11 2AR 1 This page is intentionally left blank...
Страница 191: ...3 2 62 2AR 1 This page is intentionally left blank...
Страница 196: ...3 2 61 2AR 1 This page is intentionally left blank...
Страница 255: ...3 2 38 2AR 1 This page is intentionally left blank...
Страница 384: ...2AR 1 3 6 15 This page is intentionally left blank...
Страница 398: ...3 6 27 2AR 1 3 Main PCB CN9 CN5 CN2 CN3 CN4 IC11 IC12 CN1 CN8 CN10 CN11 CN6 CN7...
Страница 431: ...2AR General connection diagram 3 7 43 General wiring diagram 3 7 44 2AR 1...