To perform the replacement of the blades do following steps:
The machine is equipped with the
quick blade fitting system
the blades
replacement is particularly easy, because the removal of the blades do not
requires wrenches or pneumatic tools.
Figure 19- Blade replacement
● Remove the pin
(see fig. 19 A)
from the blade mount housing
(see fig. 19 C)
● Remove the worn blade
(see fig. 19 C)
from the housing;
● Replace a new blade into the housing, instead of the worn blade. Be sure to
install the blade with the cutting edge in the same direction of the previous one
(same sense of rotation than therotor);
● Replace the pin inside the blade mount housing.
● Repeat the same procedure for the second blade of the rotor and for all the
rotors.
Blades on contiguous rotors have different orientations (right blades and left
blades): always install the new blades with cutting edge having the direction
of rotation of the rotor flange which they are connected to.
Worn blades can be very sharp! Apply extreme caution in handling.
48