© 2013 MIMAKI ENGINEERING CO.,LTD.
7.1.2
P.2
7.1.2 List of Error Messages
R.1.2
9
ERROR 151
MAIN PCB V1R2
Main board 1.2V power supply is abnor-
mal.
1. Check the output pressure of the DC power supply (36V)
and the DC power supply (5V).
2. Replace the power supply above.
3. Replace the MAIN PCB with a new one.
10
ERROR 152
MAIN PCB V2R5
Main board 2.5V power supply is abnor-
mal.
11
ERROR 153
MAIN PCB V3R3
Main board 3.3V power supply is abnor-
mal.
12
ERROR 154
MAIN PCB V05
Main board 5V power supply is abnormal.
13
ERROR 155
MAIN PCB V36-1
Main board 36-1V power supply is abnor-
mal.
14
ERROR 156
MAIN PCB V5B
Main board 5VB power supply is abnor-
mal.
15
ERROR 157
MAIN PCB VTT
Main board VTT power supply is abnor-
mal.
16
ERROR 158
MAIN PCB V36-2
Main board 36-2V power supply is abnor-
mal.
17
ERROR 18a
MAIN PCB V_CORE
Main board V_CORE power supply is
abnormal.
18
ERROR 18b
MAIN PCB V3R3B
Main board 1.5V power supply is abnor-
mal.
19
ERROR 18c
MAIN PCB V12
Main board 12V power supply is abnor-
mal.
20
ERROR 15f
HEAD DRIVE HOT
COM driver becomes the high tempera-
ture.
1. Check the operation of the HDC PCB cooling fan.
2. Disconnect and connect the FFC located between the
HDC PCB and the MAIN PCB.
3. Replace the HDC PCB with a new one.
4. Replace the Print Head with a new one
.
21
ERROR 171
NEW HEAD CONNECT
New Print Head was recognized.
Compare S/N written in the head memory
with S/N stored in the machine.
It is normal that an error occurs only at the time of the first
start after having connected a new head.
It is abnormal that an error occurs at the time of start every
time..
1. Check connection between the HDC PCB from the Print
Head
2. Replace the HDC PCB with a new one.
3. Replace the Print Head with a new one
.
22
ERROR 186
HDC OVERFLOW
Wave shape overflow
Wave shape data is abnormal.
1. Pull out/ insert cable between HDC PCB and MAIN PCB.
(FFC changes PCB, Optical conversion PCB)
2. Replace the HDC PCB with a new one.
3. Replace the Optical conversion PCB with a new one.
4. Replace the FFC changes PCB with a new one.
5. Replace cable between HDC PCB and MAIN PCB.
6. Replace the MAIN PCB with a new one.
23
ERROR 186
HDC UNDERFLOW
Wave shape underflow
Wave shape data is abnormal.
24
ERROR 187
HDC SLEW RATE
Wave shape slew rate error
Wave shape data is abnormal.
25
ERROR 188
HDC MEMORY
Wave shape memory error
At wave shape memory writing, it cannot
be written due to address conflict.
26
ERROR 18e
FLS NOT COMP [12__]
Flashing control error
Flashing for the head which is connected
the HDC PCB that displayed number on
the LCD can not be completed.
1. Pull out/ insert cable between HDC PCB and MAIN PCB.
(FFC changes PCB, Optical conversion PCB)
2. Replace the HDC PCB with a new one.
3. Replace the Optical conversion PCB with a new one.
4. Replace the FFC changes PCB with a new one.
5. Replace cable between HDC PCB and MAIN PCB.
6. Replace the MAIN PCB with a new one.
7. Replace the Print Head which is connected HDC PCB that
displays error with a new one
.
27
ERROR 18f
OFFSET START [12__]
Control error to Head voltage
Offset of the HDC PCB that displayed
number on the LCD can not be started.
28
ERROR 18f
OFFSET END [12__]
Control error to Head voltage
Offset of the HDC PCB that displayed
number on the LCD can not be ended.
List of Error Messages ?2/5?
No.
LCD
Cause
List of Countermeasures
MAINTENANCE MANUAL > Troubleshooting > Details on Errors and Malfunctions > List of Error Messages
Model SWJ-320S Issued 2012.07.19 Revised 2013.03.08 F/W ver 1.0 Remark
1.2