© 2013 MIMAKI ENGINEERING CO.,LTD.
6.7.6
P.1
R.1.0
MAINTENANCE MANUAL > Disassembly and Reassembly > Repeated winding relations > Take-up Motor Relay
Model
SWJ-320S
Issued 2012.07.19 Revised
F/W ver
Remark
1.0
6.7.6 Take-up Motor Relay
Work procedures
1. Turn off the main power supply and remove the power plug
from the main body.
2. Remove the following covers.
• Feeding/take-up left side cover
3. Cut the insulation lock tie, and remove the relay from relay
socket pulling out it upward.
キ
4. Reverse the disassembly procedure for reassembly.
After turning off the sub and main power switches, unplug the power cord. Make sure to take 15
minutes before restarting the operation. It is very dangerous if sleep mode functions mistakenly
during the operation.
Additionally, if electric charges are still remaining, it may cause damage to electronic parts or the like.
Take-up Motor assy.
Feeding/take-up left side cover
Take-up Motor Relay
Relay socket
Relay
Insulation lock tie
For the feeding motor relay and the take-up motor
relay, use the same one.
Narrower pitch
Wider pitch
Lever (yellow)
When the relay is mounted, turn the side of wider
pin-pitch to the lever (yellow) side, and insert it
not to bend the pins of bottom side of relay.