© 2013 MIMAKI ENGINEERING CO.,LTD.
2.3.8
P.1
R.1.0
MAINTENANCE MANUAL > Electrical Parts > Circuit Board Specifications > FFC Changes PCB assy.
Model
SWJ-320S
Issued 2012.07.19 Revised
F/W ver.
Remark
1.0
2.3.8 FFC Changes PCB assy.
Outline
Unit name: FFC Changes PCB assy.
Main specifications
The main PCB and the HDC PCB are relayed by this PCB. The PCB is placed within the electrical box and on the
carriage, and converts the FFC to the cable for the cable bear.
List of Connectors
Electrical box side
Carriage side
*For the details of connecting destinations, refer to the block diagram.
Parts No.
Pin
Connected to:*
Connecting destination CN
Remarks
CN1
30
EPL Main PCB assy
CN6
Connector for FFC
CN2
14
FFC Changes PCB assy.
CN2
CN3
3
CN4
6
CN5
10
Parts No.
Pin
Connected to:*
Connecting destination CN
Remarks
CN1
30
HDC PCB assy.
CN2
Connector for FFC
CN2
14
FFC Changes PCB assy.
CN2
CN3
3
CN4
6
CN5
10