© 2013 MIMAKI ENGINEERING CO.,LTD.
6.6.1
P.1
R.1.0
MAINTENANCE MANUAL > Disassembly and Reassembly > Pressurizing relations > Air Tank Sensor assy.
Model
SWJ-320S
Issued 2012.07.19 Revised
F/W ver
Remark
1.0
6.6.1 Air Tank Sensor assy.
Work procedures
1. Turn off the main power supply and remove the power plug
from the main body.
2. Open the cover LR.
3. Remove the screw, and remove the BKT.
4. On the back side of bracket, disconnect the connector between
the air tank sensor cable and the junction cable.
5. Disconnect the air tubes (2 positions).
6. Reverse the disassembly procedure for reassembly.
Backside of machine
Air tank sensor assy.
4
3
2
1
Air tank sensor assy.
Bracket
screw(x2)
Air tube
In case of the replacement of plural air tank sen-
sor assy., make some marking to the connection
connectors and the air tubes, and connect them
correctly.
The connecting destinations of each tank and junc-
tion cable as follows:
Black: Tank 4
Blue: Tank 3
Red: Tank 2
Yellow: Tank 1
Pressure pump assy.
Backside of bracket