© 2013 MIMAKI ENGINEERING CO.,LTD.
4.2.5
P.2
4.2.5 [HEAD ADJUST] SLANT ADJUST
R.1.0
Head slant check procedure
1. Select [#ADJUST] -> [HEAD ADJUST] -> [SLANT ADJUST]
from the operation menu.
2. Select HEADline1.
3. Press the [ENTER] key to print the pattern.
[ENTER]: starts printing pattern.
[FUNCTION]: Cap OFF
[CLEANING]: Cleaning is curried out.
[
] / [
]/[
] / [
]:enters into the jog mode (moves the
origin of the pattern)
Slant adjustment procedure
1. Confirm whether quantity of biggest gap by each scan is
settled 30
μ
m. If there is a head whose gap is out of the
standard, carry out the following adjustment.
< L O C A L >
w i d t h : 10 0 0 m m
F U N C T I ON
# A D J U S T
[ENT]
# A D J U S T
H E A D A DJ U S T
[ENT]
[FUNCTION]
# H E A D A D J U S T
S L A N T A D J U S T
[ENT]
# S L AN T A D J US T
P R I NT S T A R T
[ENT]
Do not perform this adjustment with the carriage
located on the Station Assy (cap). Make sure to cap
off.
Tolerable range:
30
μ
m
MAINTENANCE MANUAL > Adjustment > Adjustment Items > [HEAD ADJUST] SLANT ADJUST
Model
SWJ-320S
Issued 2013.03.08 Revised
F/W ver
2.20
Remark
1.0