© 2013 MIMAKI ENGINEERING CO.,LTD.
6.4.14
P.1
R.1.0
MAINTENANCE MANUAL > Disassembly and Reassembly > Electrical Parts > Suction Fan Controller assy.
Model
SWJ-320S
Issued 2012.07.19 Revised
F/W ver
Remark
1.0
6.4.14 Suction Fan Controller assy.
Work Procedures
1. Turn off the main power supply and remove the power plug
from the main body.
2. Pull out the
suction power adjustment knob
to the front direc-
tion.
3. Remove the nut of the suction fan controller shaft part.
キ
4. Open the left electrical BOX cover.
5. Remove all connectors of the suction fan controller assy.
6. Remove the screw, and remove the cooling fan.
7. Unscrew the spacer bolts, and remove the suction fan controller
assy.
8. Reverse the disassembly procedure for reassembly.
After turning off the sub and main power switches, unplug the power cord. Make sure to take 15
minutes before restarting the operation. It is very dangerous if sleep mode functions mistakenly
during the operation.
Moreover, the PCB may be damaged in case electric charge still remains inside.
Outside of Left electrical box cover
Suction fan controller assy.
Suction fan controller assy.
Inside of Left electrical box cover
Suction power adjustment knob
Nut
Screw(x4)
Connetor 1
Connetor 2
Cooling fan
Spacer bolt(x4)
Suction fan con-
troller assy.