© 2013 MIMAKI ENGINEERING CO.,LTD.
3.3.6
P.1
R.1.0
MAINTENANCE MANUAL > Workflow > Electrical Parts > Replacement of the 180 LPI Encoder Sensor
Model
SWJ-320S
Issued 2012.07.19 Revised
F/W ver
Remark
1.0
3.3.6 Replacement of the 180 LPI Encoder Sensor
List of replacement procedures
Item
Work operation
Description
Ref.
Covers
1.
Power OFF
Turning the main power OFF.
* Be sure to turn the main power OFF since the power
comes ON due to the sleep control if turned to OFF by
the power SW on the panel.
---
2.
Removal of covers, etc.
Remove the following covers.
Carriage cover
SD PCB cover
Encoder Sen-
sor
3.
Encoder Sensor replacement
Check/
Adjustment
4.
Encoder position adjustment
Checking the encoder mounting at the specified position.
5.
Power ON
Turning the power ON to start the machine.
---
6.
Encoder check
Carry out the encoder check to confirm it functions nor-
mally.
Covers
7.
Mounting of the covers.
Mount the covers that have been removed.
For the power OFF, be sure to turn the main power OFF.
If the sleep function works accidentally during the operation, it is very dangerous.
180 LPI Encoder Sensor