© 2013 MIMAKI ENGINEERING CO.,LTD.
4.2.13
P.2
4.2.13 HEAD WASH
R.1.2
6. Move the Carriage to left maintenance position with press
[ENTER] key.
7. Insert the air purge jig into the ink port, and purge the washing
liquid.
8. Manually perform wiping.
9. Move the Carriage to the capping position with press [ENTER]
key.
10. Remove the wash bottle, and press the [ENTER] key.
11. .Repeat above procedure steps from 5. to 8.
12. Move the Carriage to the capping position with press [ENTER]
key.
13. Clean the wiper and cap.
Press [ENTER] key after cleaning is completed, and then finish
the procedure.
Purge button
INK PORT WASHING
START
[ENT]
Carriage moves to Left
maintenance position.
Ink discharge tray
Air purge jig
Set so that the tips of the air purge jig come into
contact with the bottom of the discharge tray.
Counter flow of the washing liquid and inflow of
the air may be occurred.
Purge the air and then discharge the washing liquid
from the tip of the jig by pressing the purge button,
and then end after it is completed.
INK PORT WASHING
COMPLETED
[ENT]
REMOVE WASH BOTTLE
COMPLETED
[ENT]
Carriage moves to Capping
position.
WASHING
PLEASE WAIT
INK PORT DISCHARGE
COMPLETED
[ENT]
WIPER&CAP CLEANING
COMPLETED
[ENT]
cap cleaning
wiper cleaning
Carriage moves to Capping
position.
MAINTENANCE MANUAL > Adjustment > Adjustment Items > HEAD WASH
Model
SWJ-320S
Issued 2012.07.19 Revised 2013.03.08 F/W ver
1.0
Remark
1.2