© 2013 MIMAKI ENGINEERING CO.,LTD.
4.2.24
P.1
R.1.0
MAINTENANCE MANUAL > Adjustment > Adjustment Items > Temperature control Upper limit value setting
Model
SWJ-320S
Issued 2012.07.19 Revised
F/W ver
1.0
Remark
1.0
4.2.24 Temperature control Upper limit value setting
Outline
Setting the upper limit value of temperature control when shipped, to the upper limit value of this machine.
Upper limit value: 70°C (applied to the Post-, Pre- and Print heater)
Setting procedure
1. Turn the power ON.
2. Shift in the setting mode by pressing [SET] and [<] for more
than 3 seconds simultaneously.
3. Set “0000” to “0001” by pressing [^].
4. Press [SET].
5. Set it to “0070” (Upper limit temperature) by pressing [^], [v]
and [<].
6. Press [SET].
7. End the setting mode by pressing [SET] and [<] for 3 seconds
simultaneously.
Checking of setting
1. Check that the initial indication is “70” (at shipment: 400) by
switching the power switch of heater from "OFF" to “ON”.
Control key
Set temperature
Current temperature
2 4
5
0
PV
Power ON
SV
C o d
0 0 0
0
PV
[SET] and [<] simultaneously pressing (more than 3 sec)
SV
C o d
0 0 0
1
PV
SV
S L H
0 4 0
0
PV
SV
S L H
0 0 7
0
PV
SV
S L L
0 0 0
0
PV
SV
2 4
5
0
PV
SV
0 0
7
0
Power ON
PV
SV