MAINTENANCE MANUAL > Workflow > Electrical Parts > Replacement of the Main PCB assy.
Model
SWJ-320S
Issued 2012.07.19 Revised 2013.08.28 F/W ver
Remark
1.1
3.3.1 Replacement of the Main PCB assy.
Outline
If Main PCB assy. has replaced, various parameters must be registered to Main PCB ROM after the replacement.
Considerable time is required to readjust and reconfigure these settings. Therefore, for ease of use and better printing
quality, copy (upload) the setting value to a PC before replacement, and write (download) the copied settings onto the
Main PCB from the PC after replacement.
List of replacement procedures
After turning off the sub and main power switches, unplug the power cord. Make sure to take 15
minutes before restarting the operation. It is very dangerous if sleep mode functions mistakenly
during the operation.
Moreover, the PCB may be damaged in case electric charge still remains inside.
Also, there is a possibility of electric shock because of high power voltage applied to the high-pres-
sure part of the DC power supply unit. Take care to avoid contact with it.
If it is impossible to upload the parameters, conduct Parameter Draw to note the setting values.
Then manually register the values after replacing the PCB.
Item
Work operation
Description
Ref.
Advance
preparation
1.
Parameter upload
Before the printed-circuit board is replaced, upload its
parameter to the PC.
Main PCB
assy.
2.
Power OFF
Power cable removing from main
body
Turing the main power OFF, and then removing the power
cable from the main body.
---
3.
Main PCB assy. replacement
Check/
Adjustment
4.
Power ON
Connecting the power cable to the main body, and starting
the machine.
---
5.
Power voltage adjustment
Monitoring the power with a tester and adjusting the volume
of DC power supply(DC37V).
6.
Parameter download
Download the parameters which were uploaded in operation
“1”.
Main PCB assy.