5-10
6
Rotate the adjustment screw of the throttle valve to
adjust the pressure so that it becomes the proper
value.
• Proper value of negative pressure: -1.90kPa
Proper value of positive pressure: 15.00kPa
• As the negative pressure changes between ±0.1 and 0.2kPa, adjust so that the intermediate value may
become the target pressure.
As the positive pressure changes between ±1.0 and 2.0kPa, adjust so that the intermediate value may
become the target pressure.
• Status of lamp and buzzer for each pressure value
7
Press the
key.
• The error is released and the pressure control starts.
• Pressure is informed with the buzzer and the ink cartridge LED as well as the screen
display.
• For the negative pressure, the buzzer stops within the range of ±0.1kPa. For the
positive pressure, the buzzer stops within the range of ±1.0kPa.
Pressure
Cartridge LED
Buzzer
Positive pressure Negative pressure
High
~ 8.49
~ -1.16
Sounds
8.50 ~ 9.49
-1.26 ~ -1.35
9.50 ~ 10.49
-1.36 ~ -1.45
10.50 ~ 11.49
-1.46 ~ -1.55
11.50 ~ 12.49
-1.56 ~ -1.65
12.50 ~ 13.49
-1.66 ~ -1.75
13.50 ~ 14.49
-1.76 ~ -1.85
Stops
Proper
value
14.50 ~ 15.49
-1.86 ~ -1.95
Stops
Low
15.50 ~ 16.49
-1.96 ~ -2.05
Stops
16.50 ~ 17.49
-2.06 ~ -2.15
Sounds
17.50 ~ 18.49
-2.16 ~ -2.25
18.50 ~ 19.49
-2.26 ~ -2.35
19.50 ~ 20.49
-2.36 ~ -2.45
20.50 ~ 21.49
-2.46 ~ -2.55
21.50 ~ 22.49
-2.56 ~ -2.65
22.50 ~
-2.66 ~
• When an error occurs even after you adjusted the pressure, contact your local distributor to call for
service.
PRESSURE
=
- 1 . 9 0 k P a
P L EASE WA I T
Содержание JV400-130SUV
Страница 1: ...MIMAKI ENGINEERING CO LTD URL http eng mimaki co jp D202394 17 Original instructions ...
Страница 58: ...2 28 ...
Страница 73: ...3 15 1 1 3 Convenient use 5 6 9 Press the key several times to end the setting ...
Страница 100: ...3 42 ...
Страница 162: ...5 20 ...
Страница 179: ...Function Flowchart 6 17 Appendix 6 ...
Страница 187: ...Function Flowchart 6 25 Appendix 6 ...
Страница 192: ...6 30 ...
Страница 194: ...KT FW 3 50 MIMAKI ENGINEERING CO LTD 2016 ...