When Nozzle Clogging Cannot Be Solved
4-25
1
1
1
4
Routine Maintenance
11
Press the
key.
• The cleaning solution filled in the cap is absorbed.
• The screen on the right is displayed only for the duration set in the
step 10.
• It returns to the step2 after the duration.
• When nozzle missing is not cleared even after nozzle recovery (
P.4-28) or this washing is carried
out several times, contact the distributor in your region or our service office.
• When this machine is not filled with cleaning solution for maintenance, do the following:
(1)
Perform the operations in Steps 1 to 5.
(2)
Fill up the cap with cleaning solution for maintenance, using a syringe.
(3)
Perform the operations in Step 7 and later.
P L EASE WA I T
0 0 : 0 0
* * C L EAM I NG * *
P L EASE WA I T