77
Trouble shooting
Turn the machine’s wall switch off and on again.
Start a program.
Error code returns
No error code
Disconnect connector X3 by motor and use an
ohmmeter to check the motor windings. Check
between 1 - 2, 2 - 3 and 1 - 3. Correct reading:
2.9
Ω
.
Resistances correct
Any resistance wrong
Disconnect connectors X312 by motor control
unit and X3 by motor. Check wiring by using
ohmmeter to measure the three conductors as
follows:
X312:
X3:
6
-
1
7
-
2
8
-
3
Also check between the three conductors to
eliminate shorts between any two.
Wiring OK
Wiring faulty
35E
Motor control unit indicating
short-circuit between outputs
for motor windings.
Error codes which may arise on the control panel display
Connector X3, male, to
motor control unit
3402
1
3
9
7
2
1
8
1
3
9
7
2
Connector X3, wiring to
motor control unit.
Connector X312, wiring
to motor
3401
3403
Error code/symptoms
Fault-finding
Transient fault. No action
required.
Check the wiring and replace
if necessary.
Fault in motor control unit
output stage. Replace motor
control unit.
Replace motor.
Cause/Action