Trouble shooting
Error codes which may arise on the control panel display
Error code/symptoms
Fault-finding
Cause/Action
Turn the machine’s wall switch off and on again.
Start a program.
Error code returns
No error code
Remove PCB connector X74 on program control
unit PCB. Turn the machine’s wall switch off and
on again. Start a program. Check whether the
error displayed is 04E or 05E.
04E
05E
Put back X74. Disconnect the link between
wiring and sensor by the temperature sensor.
Turn the machine’s wall switch off and on again.
Start a program. Check whether the error
displayed is 04E or 05E.
05E
04E
05E
Temperature sensing
indicates temperature above
98
°
C (short-circuit).
2316
X74
2
1
3399
Temperature
sensor
Transient fault.
Fault in temperature sensing
device on program control
unit PCB. Replace PCB.
Temperature sensor faulty.
Replace sensor.
Fault in wiring to temperature
sensor. Check wiring and
replace if necessary.
Rough values on the temp.
sensor
T (
°
C)
R (ohm)
19
6100
20
5850
21
5600
22
5350
23
5100