M‐Thermal Split
201909 25
P
art 3 ‐
Con
tr
ol
6.6
Smart grid control
Unit adjusts the operation according to different electrical signals to realize energy saving.
Free electric energy signal: DHW mode turn on, the setting temperature will be changed to 70
℃
automatically, and the
TBH operate as below:T5<69. the TBH is on, T5
≥
70, the TBH is off. The unit operate in cooling/heating mode as the
normal logic.
Common electric energy signal: unit operates according to users’ need.
Expensive electric energy signal: only available for cooling or heating mode and user can set the maximum operating time.
Midea CAC Confidential
Содержание SMK-60/CGN8
Страница 1: ...M Thermal Split Series Commercial Air Conditioners R32 Service Manual Midea CAC Confidential...
Страница 3: ...M Thermal Split 2 201909 Midea M Thermal Split Service Manual Midea CAC Confidential...
Страница 7: ...M Thermal Split 6 201909 Midea M Thermal Split Service Manual Midea CAC Confidential...
Страница 15: ...M Thermal Split 14 201909 Midea M Thermal Split Service Manual Midea CAC Confidential...