94 Operator Maintenance
---------------------------------------------------------------------------------------------------------------------------------------------------------------------
________________________________________________________________________________________________
MICROPLEX
Operator’s Manual SOLID 166E
Edition 1.1
2.
Remove the main charger, the transfer charger, and the pre-
charger from the engine, then check whether or not wires are
stained black. (Compare section 6.2.2.)
3.
Concerning the transfer/transport unit, turn the green lever of
transfer/transport unit counterclockwise, and then pull out the
transfer/transport unit outwardly after confirming that the
transfer unit is in the down position. Check whether or not
paper dust has been stacked in the concave on the transport
surface.
4.
Lower the transport surface of the transfer/transport unit.
5.
Before pulling out the fuser unit the bracket (see following figure)
has to be disassembled.
Caution: It is not allowed to use the printer while the bracket is
disassembled.
Fig. 6.1.a Disassembling the bracket of the fuser unit
6.
Pull out the fuser unit from the engine.
7.
After that, turn the fuser unit counterclockwise, check whether or
not the glass surface is stained black by toner, and whether or
not paper dust has been stacked on the glass surface.
Bracket for
the fuser unit
Fuser unit