82 Panel Functions
_______________________________________________________________________________________________
________________________________________________________________________________________________
MICROPLEX
Operator’s Manual SOLID 166E
Edition 1.1
5.24. Image Shifting to the X-Direction
This function shifts the print image in relation to the paper to the
X-direction (crosswise the print direction). Because the paper feed
is always centered to the middle in the SOLID 166E, the image
shifting might be necessary when using e.g. special paper formats
to shift the X-coordinate zero to the left paper edge.
Panel display
[SOLID 166E ]
[Menu Level 1
]
(
(
(
[Engine
]
[Resolution
]
(
(
(
[Image X-Pos.
]
[Image X-Pos.
xxx ]
(
(
(
[Image X-Pos. 160
]
[Save as Setup? ]
Notes
Turn the printer OFF LINE with this key.
Press the NEXT or PREVIOUS key until
[Engine ] is displayed.
Press the NEXT or PREVIOUS key until
[Image X-Pos.] is displayed.
The panel function Image Shifting to the X-
Direction is selected.
xxx = currently set value.
(Default value =128).
Operating the NEXT or PREVIOUS key the
value for the image shift can be altered.
Values from 0 up to 254 are settable, so
a max. image shifting of appr. ±1 ¼ Inch
(approx. ±32 mm) can be reached.
Now the new image X-Position is saved
In addition this new value can be saved
as setup value (using the ENTER key),
before the printer is turned ON LINE