Page 147
Error message
Meaning of the error message Measures
Main
index
Sub
index
1
Digital inputs - Signal level error Cause:
Exceeding / violation of discrepancy
time with multi-channel inputs
(DIN40 ... DIN43, two-handed
control device, mode selector
switch).
Action:
Check the external active and
passive sensors – do they switch on
two channels and simultaneously
(within the parameterised
discrepancy time).
Two-handed control device: Check
how the device is operated by the
user – are both pushbuttons
pressed within the discrepancy
time? Give training if necessary.
Check the set discrepancy times –
are they sufficient?
2
Digital inputs - Test pulse error
Cause: One or more inputs (DIN40 ... DIN49)
were configured for the analysis of the
test pulses of the outputs (DOUT40 ...
DOUT42). The test pulses from DOUTx
do not arrive at DIN4x.
Action:
Check the wiring (shorts after 0 V,
24 V, cross circuits).
Check the assignment – correct
output selected / configured for test
pulse?
6
Electronics temperature too
high
Cause: The safety module's temperature
monitor has been triggered; the
temperature of µC1 or µC2 was below
-20° or above +75°C.
Action:
Check the operating conditions
(ambient temperature, control
cabinet temperature, installation
situation in the control cabinet).
If the servo drive is experiencing
high thermal load (high control
cabinet temperature, high power
consumption / output to motor, large
number of occupied slots), a servo
drive of the next higher output level
should be used.
Product Manual „Servo drives ARS 2100 SE“
Version 5.0