11.1.8 Initial operation status
Servo drives, which are sent to Metronix for service, will be equipped with a different firmware and
other parameters for testing purposes.
Before the next initial operation at the customer the servo drive ARS 2100 SE must be parameterised
again. The parameterisation software Metronix ServoCommander
®
queries the initial operation status
and asks the user to parameterise the servo drive. At the same time the device shows an “A” on the
seven-segment display to indicate that it is ready but not yet parameterised.
11.1.9 Rapid discharge of the DC bus
If the system detects a failure of the mains supply, the DC bus is rapidly discharged within the safety
period in accordance with EN 60204-1.
Delayed activation of the brake chopper according to power classes in the case of parallel operation
and mains supply failure ensures that the main energy during rapid discharge of the DC bus is taken
over through the braking resistors of the higher power classes.
11.1.10
Operating hours counter
An operating hours counter is implemented, which has been designed for at least 200,000 operating
hours. The operating hours counter is displayed in the parameterisation software Metronix
ServoCommander
®
.