Page 134
Error message
Meaning of the error message Measures
Main
index
Sub
index
3
Positioning start rejected:
incorrect operating mode
The change of the mode of operation could not
be performed by the position set.
4
Positioning start rejected:
homing required
Reset the optional parameterisation “homing
required”.
Perform a new homing run.
5
Rotary axis: direction of rotation
not permissible
In accordance with the selected mode, the
calculated direction of rotation of the rotary axis
is not permissible.
Check the selected mode.
9
Error during the start of the
positioning run
Check the speed and acceleration parameters.
43
0
Limit switches: negative
setpoint blocked
The drive has left the intended motion range.
Technical defect in the system?
Check the limit switches.
1
Limit switches: positive setpoint
blocked
2
Limit switches: positioning
suppressed
44
0
Error in the cam disc tables
Check whether the index has been assigned
correctly.
Check whether there are cam discs present in
the device.
1
Cam disc: general homing error Ensure that the drive has been homed prior to
the activation of the cam disc.
Delete the “homing required” option.
Ensure that a cam disc cannot be started during
a homing run.
47
0
Timeout (set-up mode)
Check the processing of the request by the PLC.
Speed threshold too low or timeout too small?
48
0
Drive not referenced
Switch to positioning and perform a homing run.
50
0
CAN:
too many synchronous PDOs
Deactivate the PDOs or increase the SYNC
interval. The maximum number of PDOs must
not be greater than the factor tp between the
position controller and IPO (menu:
Parameters/Controller parameters/Cycle times).
1
SDO error occurred
Please contact the Technical Support.
Product Manual „Servo drives ARS 2100 SE“