Error message
Meaning of the error message Measures
Main
index
Sub
index
21
0
Error 1 current measurement U Please contact the Technical Support.
1
Error 2 current measurement V
2
Error 2 current measurement U
3
Error 1 current measurement V
22
0
PROFIBUS:
incorrect initialization
Technology module defective?
Replace the technology module.
If necessary, contact the Technical Support.
1
PROFIBUS: reserved
Please contact the Technical Support.
2
PROFIBUS:
communication error
Check the slave address.
Check the bus terminators.
Check the cabling.
3
PROFIBUS:
invalid slave address
Incorrect slave address. Please select another
slave address.
4
PROFIBUS: error in value
range
Mathematical error during the conversion of
physical units. The value range of the data and of
the physical units do not match (fieldbus display
units).
If necessary, contact the Technical Support.
23
0
No consumable record
Position save and restore failed, homing
required.
1
Record with invalid checksum
2
Flash content inconsistent
25
0
Invalid device type
Please return the device to our sales partner.
1
Device type not supported
2
HW revision not supported
Check the firmware version.
If necessary, request an update from the
Technical Support.
3
Device functionality restricted!
Please return the device to our sales partner.
4
Invalid power module type
Check the firmware version.
If necessary, request an update from the
Technical Support.
Product Manual „Servo drives ARS 2100 SE“
Version 5.0