Page 121
Error message
Meaning of the error message Measures
Main
index
Sub
index
8
Servo drive switched on
Information: Entry in permanent event memory.
No measures required.
9
Servo drive safety parameters
revised
Information: Entry in permanent event memory.
No measures required.
11
FSM: Module change (previous
type): Permanent event
memory and FSM module
Information: Entry in permanent event memory.
No measures required.
12
FSM: Module change (current
type): Permanent event
memory and FSM module
Information: Entry in permanent event memory.
No measures required.
21
Log entry from the FSM-MOV:
Permanent event memory and
FSM module
Information: Entry in permanent event memory.
No measures required.
01
0
Stack overflow
Incorrect firmware?
If necessary, reload the standard firmware.
Contact the Technical Support.
02
0
Undervoltage of the DC bus
circuit
Error priority set too high?
Check the power supply.
Check (measure) the DC bus circuit voltage.
Check the response threshold of the DC bus
circuit monitoring system.
03
0
Motor overtemperature
(analogue)
Motor too hot? Check the parameterization
(current controller, current limits).
Suitable sensor?
Sensor defective?
Check the parameterization of the sensor or the
characteristic curve of the sensor.
If the error occurs also when the sensor is
bypassed, return the device to our sales partner.
1
Motor overtemperature
(digital)
2
Motor Overtemperature
(analogue): wire break
Check the connecting cables of the temperature
sensor (broken wire).
Check the parameterisation of wire break
detection system (threshold value).
Product Manual „Servo drives ARS 2100 SE“
Version 5.0