Page 150
Error message
Meaning of the error message Measures
Main
index
Sub
index
6
Error in cross-comparison for
processors 1 - 2
Cause: Timeout during cross-comparison (no
data) or cross-comparison faulty (data
for µC1 and µC2 are different).
Error in cross-comparison for digital
I/O.
Error in cross-comparison for
analogue input.
Error in cross-comparison for
internal operating voltage
measurement (5 V, 3.3 V, 24 V) and
reference voltage (2.5 V).
Error in cross-comparison for
SIN/COS angle encoder analogue
values.
Error in cross-comparison for
programme sequence monitoring.
Error in cross-comparison for
interrupt counter.
Error in cross-comparison for input
map.
Error in cross-comparison for
violation of safety conditions.
Error in cross-comparison for
temperature measurement.
Action:
This is an internal error in the module
that should not occur during operation.
Check the operating conditions
(temperature, air humidity,
condensation).
Check the EMC wiring as specified
and screening design; are there any
external interference sources?
Safety module may be faulty – is
error eliminated after replacing the
module?
Check whether new firmware for the
servo drive or a new version of the
safety module is available from the
manufacturer.
Product Manual „Servo drives ARS 2100 SE“
Version 5.0