DS3 UNI PORT CONFIGURATION
99
76-02-031E
14. 6 DS3 ATM set-up
The DS3 port ATM characteristics are set using the path:
MAIN SET-UP / ATM SET-UP / DS3 PORT
Figure 14.5 DS3 ATM set-up
14 . 6. 1 Forward Idle cells
This option allows idle cells (cells that match the idle cell mask) to be forwarded rather than
deleted.
14 . 6. 2 HCS coset
The
HCS COSET
option allows the HCS to be X-ORed with 0x55 so that the idle cell HCS
is non-zero.
14 . 6. 3 Payload scrambling
PAYLOAD SCRAMBLING
prevents cell traffic from ghosting Frame Alignment patterns and
thereby causing false framing. The default value is disabled.
14 . 6. 4 Idle cell payload
The
IDLE CELL PAYLOAD
option allows special patterns to be configured in to idle cells.
Most ATM UNI devices identify idle cells from the header alone (VPI, VCI, etc set to 0) and
not the payload. Therefore to give some transmission traffic density the payload may be
configured to be non-zero. The 16-bit pattern is repeated 24 times in the cell.
DS3 PORT
Forward idle cell
no
HCS coset
Enabled
Payload scrambling Enabled
Idle cell payload
0000000000000000
Содержание ATM CBR DSU
Страница 2: ......
Страница 4: ......
Страница 10: ......
Страница 16: ...INTRODUCTION 76 02 031E 6...
Страница 20: ...STATUTORY INFORMATION 76 02 031E 10...
Страница 34: ...INSTALLING SETTING UP 76 02 031E 24...
Страница 56: ...CONFIGURING THE ATM CBR DSU 76 02 031E 46...
Страница 78: ...ANALYSING PERFORMANCE 76 02 031E 68...
Страница 88: ...E1 CBR PORT CONFIGURATION 76 02 031E 78...
Страница 92: ...E2 CBR PORT CONFIGURATION 76 02 031E 82...
Страница 96: ...E3 CBR PORT CONFIGURATION 76 02 031E 86...
Страница 100: ...DS3 CBR PORT CONFIGURATION 76 02 031E 90...
Страница 106: ...E3 UNI PORT CONFIGURATION 76 02 031E 96...
Страница 112: ...DS3 UNI PORT CONFIGURATION 76 02 031E 102...
Страница 120: ...SDH Sonet UNI PORT CONFIGURATION 76 02 031E 110...