INTRODUCING THE ATM CBR DSU
13
76-02-031E
3. 5 Remote Management Port
This port is labelled
MAN PORT
on the rear panel. The LM1100 SNMP Enabler option gives
access to the SNMP network management system via an IEEE 802.3/10BaseT interface on
the rear of the DSU.
The Management port is regarded as a SELV port within the scope of
EN41003.
The layout of this port’s RJ45 connector is shown below:
Figure 3.6 Management port layout
3. 6 Alarm Extension
This port is labelled
ALARM EXT
on the rear panel. The port is either a 6-pin mini-DIN
connector or a 9-pin D-type connector, allowing you to connect the major and minor alarm
relay contacts within the DSU to a remote indicator, such as a bell or a lamp. The maximum
current rating for the alarm relay contacts is 2 amps at 30VDC, or 0.5 amps at 120VAC for
resistive loads. The two types of connector pins are described below.
Note:
The Alarm Relay port is regarded as a SELV port within the scope of EN41003.
Figure 3.7 6-pin mini-DIN connector layout
Pin
Signal
1
Tx Data + ve
2
Tx Data - ve
3
Rx Data + ve
4
Not connected
5
Not connected
6
Rx Data - ve
7
Not connected
8
Not connected
Pin
Function
1
Major common
2
Minor N/C
3
Major N/O
4
Minor N/O
5
Major N/C
6
Minor common
Содержание ATM CBR DSU
Страница 2: ......
Страница 4: ......
Страница 10: ......
Страница 16: ...INTRODUCTION 76 02 031E 6...
Страница 20: ...STATUTORY INFORMATION 76 02 031E 10...
Страница 34: ...INSTALLING SETTING UP 76 02 031E 24...
Страница 56: ...CONFIGURING THE ATM CBR DSU 76 02 031E 46...
Страница 78: ...ANALYSING PERFORMANCE 76 02 031E 68...
Страница 88: ...E1 CBR PORT CONFIGURATION 76 02 031E 78...
Страница 92: ...E2 CBR PORT CONFIGURATION 76 02 031E 82...
Страница 96: ...E3 CBR PORT CONFIGURATION 76 02 031E 86...
Страница 100: ...DS3 CBR PORT CONFIGURATION 76 02 031E 90...
Страница 106: ...E3 UNI PORT CONFIGURATION 76 02 031E 96...
Страница 112: ...DS3 UNI PORT CONFIGURATION 76 02 031E 102...
Страница 120: ...SDH Sonet UNI PORT CONFIGURATION 76 02 031E 110...