E3 UNI PORT CONFIGURATION
95
76-02-031E
13. 11 E3 Alarm responses
In the presence of an alarm condition on the E3 port the following responses are established:
Figure 13.9 E3 Alarm responses
Alarm
Response
LOS
MAJOR alarm lamp lights. E3 port transmits RAI
Other port transmits according to its AIS/RAI forwarding configuration
LOF
MAJOR alarm lamp lights. E3 port transmits RAI
Other port transmits according to its AIS/RAI forwarding configuration
SQ
MAJOR alarm lamp lights. E3 port transmits RAI
Other port transmits according to its AIS/RAI forwarding configuration
AIS
MINOR alarm lamp lights. E3 port transmits RAI
Other port transmits according to its AIS/RAI forwarding configuration
RAI
MINOR alarm lamp lights
Other port transmits according to its AIS/RAI forwarding configuration
OOSP
MINOR alarm lamp lights
ATM Layer
LOC
MINOR alarm lamp lights
Содержание ATM CBR DSU
Страница 2: ......
Страница 4: ......
Страница 10: ......
Страница 16: ...INTRODUCTION 76 02 031E 6...
Страница 20: ...STATUTORY INFORMATION 76 02 031E 10...
Страница 34: ...INSTALLING SETTING UP 76 02 031E 24...
Страница 56: ...CONFIGURING THE ATM CBR DSU 76 02 031E 46...
Страница 78: ...ANALYSING PERFORMANCE 76 02 031E 68...
Страница 88: ...E1 CBR PORT CONFIGURATION 76 02 031E 78...
Страница 92: ...E2 CBR PORT CONFIGURATION 76 02 031E 82...
Страница 96: ...E3 CBR PORT CONFIGURATION 76 02 031E 86...
Страница 100: ...DS3 CBR PORT CONFIGURATION 76 02 031E 90...
Страница 106: ...E3 UNI PORT CONFIGURATION 76 02 031E 96...
Страница 112: ...DS3 UNI PORT CONFIGURATION 76 02 031E 102...
Страница 120: ...SDH Sonet UNI PORT CONFIGURATION 76 02 031E 110...