SPECIFICATIONS
111
76-02-031E
17 SPECIFICATIONS
17. 1 CBR Ports
E1 CBR port
INTERFACE TYPE
E1
PHYSICAL (LAYER 0)
BNC, 75 Ohm coax
BARRIER:
EN 41003 compliant
DATA RATE:
2
.
048 Mbit/s per G.703
LINE CODING:
HDB3 per G.703
JITTER TOLERANCE:
per G.823
FRAMING (LAYER 1)
Unframed
PLCP (LAYER 1
1
/2)
none
ATM (LAYER 2)
none
AAL1 LAYER
5446 cells/second
ERROR TYPES:
BPV
E2 CBR port
INTERFACE TYPE
E2
PHYSICAL (LAYER 0)
BNC, 75 Ohm coax
BARRIER:
EN 41003 compliant
DATA RATE:
8
.
448 Mbit/s per G.703
LINE CODING:
HDB3 per G.703
JITTER TOLERANCE:
per G.823
FRAMING (LAYER 1)
Unframed
PLCP (LAYER 1
1
/2)
none
ATM (LAYER 2)
none
AAL1 LAYER
22468 cells/second
ERROR TYPES:
BPV