STATUTORY INFORMATION
7
76-02-031E
2 STATUTORY INFORMATION
The ATM CBR DSU family Line Ports comply with the requirements of G.703
at 2
⋅
048 Mbit/s (E1), 8
⋅
448 Mbit/s (E2), 34
⋅
368 Mbit/s (E3) and 44
⋅
736 Mbit/s (DS3).
ATM CBR DSU family products should not be connected to cabling which would be required
by BS6701 to be equipped with over-voltage protection.
2. 1 Safety
The following ports are designated SELV (Safety Extra Low Voltage) within the scope of
EN41003:
CBR LINE port
ATM UNI port
Terminal port
Management port
Alarm extension port
Users are reminded that these ports should only be connected to SELV ports on other
equipment in accordance with EN60950 clause 2.3.
2.2 Electromagnetic Compatibility
In order to ensure EMC compliance all signal and data cables and connectors must use a
screened connector shell with a screened cable. The cable screen must be terminated to the
screened connector shell and not connected to any pins of the connector. Failure to use the
correct connector may compromise EMC compliance.
2. 3 EN55022 Declaration
The ATM CBR DSU is a Class A product. In a domestic environment it may cause radio
interference in which case the user may be required to take adequate measures.
2. 4 FCC Declaration
This equipment has been tested and found to comply with the limits for a Class A digital
device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide
reasonable protection against harmful interference when the equipment is operated in a
commercial environment. This equipment generates, uses, and can radiate radio frequency
energy and, if not installed and used in accordance with the instruction manual, may cause
harmful interference to radio communications. Operation of this equipment in a residential
area is likely to cause harmful interference in which case the user will be required to correct
the interference at its own expense.
Содержание ATM CBR DSU
Страница 2: ......
Страница 4: ......
Страница 10: ......
Страница 16: ...INTRODUCTION 76 02 031E 6...
Страница 20: ...STATUTORY INFORMATION 76 02 031E 10...
Страница 34: ...INSTALLING SETTING UP 76 02 031E 24...
Страница 56: ...CONFIGURING THE ATM CBR DSU 76 02 031E 46...
Страница 78: ...ANALYSING PERFORMANCE 76 02 031E 68...
Страница 88: ...E1 CBR PORT CONFIGURATION 76 02 031E 78...
Страница 92: ...E2 CBR PORT CONFIGURATION 76 02 031E 82...
Страница 96: ...E3 CBR PORT CONFIGURATION 76 02 031E 86...
Страница 100: ...DS3 CBR PORT CONFIGURATION 76 02 031E 90...
Страница 106: ...E3 UNI PORT CONFIGURATION 76 02 031E 96...
Страница 112: ...DS3 UNI PORT CONFIGURATION 76 02 031E 102...
Страница 120: ...SDH Sonet UNI PORT CONFIGURATION 76 02 031E 110...