USER MANUAL, RSS-1000-CVSI
7000-5970
Rev.
A
page
159
of
396
2. Select desired Solder Line parameter by scrolling through the parameter list. This can be done by
swiping up or down within the gray parameter box until the desired Solder Line parameter is
highlighted. Once highlighted, the parameter will register as the selected parameter for
programming and any subsequent points programmed will follow the settings within the
highlighted solder line parameter.
3. Select desired Transition Movement that is to be exectuted from point to point. For more details
on the differences between Transition Move and Space Move, please refer to the
Profile Options
section of the manual. Once selected, the setting will be used for programming and any
subsequent points programmed will follow suit, until the setting is changed. The system allows for
profiles to have a mixture of Interpolation and Space moves. Use of one or another is application
dependent.
3.1. Pro Tip: Programming with Space Move runs the unit at very high speeds. Mistakes made
during programming at this speed can lead to longer downtimes for machines. For this
reason, good practice is to initially program using Interpolation Move. Once the profile has
been tested and deemed satisfactory, the profile can then be optimized for speed by switching
points to the Space Move within the
Edit Menu
.
Содержание RSS-1000-CVSI
Страница 21: ...USER MANUAL RSS 1000 CVSI 7000 5970 Rev A page 21 of 396 ROBOT BASE CONNECTIONS N ...
Страница 51: ...USER MANUAL RSS 1000 CVSI 7000 5970 Rev A page 51 of 396 POWERING OFF THE UNIT 1 Tap the Logout button ...
Страница 52: ...USER MANUAL RSS 1000 CVSI 7000 5970 Rev A page 52 of 396 2 Tap the Power Button ...
Страница 54: ...USER MANUAL RSS 1000 CVSI 7000 5970 Rev A page 54 of 396 REBOOTING SOFTWARE 1 Tap the Logout button ...
Страница 55: ...USER MANUAL RSS 1000 CVSI 7000 5970 Rev A page 55 of 396 2 Tap the Power Button ...
Страница 124: ...USER MANUAL RSS 1000 CVSI 7000 5970 Rev A page 124 of 396 5 Tap on the Logout button 6 Tap the Power button ...
Страница 128: ...USER MANUAL RSS 1000 CVSI 7000 5970 Rev A page 128 of 396 5 Tap on the Logout button 6 Tap the Power button ...
Страница 220: ...USER MANUAL RSS 1000 CVSI 7000 5970 Rev A page 220 of 396 5 Array Path Pattern 5 1 Vertical Zig Zag 1 4 7 2 5 8 3 6 9 ...
Страница 221: ...USER MANUAL RSS 1000 CVSI 7000 5970 Rev A page 221 of 396 5 2 Horizontal Zig Zag 1 2 3 4 5 6 7 8 9 ...
Страница 222: ...USER MANUAL RSS 1000 CVSI 7000 5970 Rev A page 222 of 396 5 3 Vertical Square Zig Zag 1 6 7 2 5 8 3 4 9 ...
Страница 223: ...USER MANUAL RSS 1000 CVSI 7000 5970 Rev A page 223 of 396 5 4 Horizontal Square Zig Zag 1 2 3 6 5 4 7 8 9 ...
Страница 224: ...USER MANUAL RSS 1000 CVSI 7000 5970 Rev A page 224 of 396 5 5 Spiral 1 2 3 8 9 4 7 6 5 ...