USER MANUAL, RSS-1000-CVSI
7000-5970
Rev.
A
page
330
of
396
MECHANICAL
ADJUSTMENT
OF
COMPUTER
VISION
CAMERA
In the event digital zoom is insufficient for a given application, the camera may be
mechanically lowered. This in turn will increase the displayed image size. However, please note
that once the Computer Vision Camera has been mechanically adjusted, ALL previously programmed
solder patterns that are associated with Fiducial Points will NO LONGER BE VALID as the camera
will require calibration. In addition, all images previously taken will no longer have the correct scaling
factor, thus making jog commands using images inaccurate. This option should only be used as
a
last resort
or prior to creation of any profiles.
1. Tap the Camera Icon to enable the Computer Vision Camera
1.1. Note: The icon will illuminate blue when active and an image should appear in the workspace.
2. Jog to a position where the fixtured printed circuit board is within view of the camera.
2.1. For optimal results, locate a specific feature on the board
3. With an M2.5 hex key, loosen the 3x socket head cap screws to the left of the computer vision
camera assembly.
4. Adjust the assembly as far down as needed, using the reference feature that is displayed.
Socket
Head Cap
Screws
Содержание RSS-1000-CVSI
Страница 21: ...USER MANUAL RSS 1000 CVSI 7000 5970 Rev A page 21 of 396 ROBOT BASE CONNECTIONS N ...
Страница 51: ...USER MANUAL RSS 1000 CVSI 7000 5970 Rev A page 51 of 396 POWERING OFF THE UNIT 1 Tap the Logout button ...
Страница 52: ...USER MANUAL RSS 1000 CVSI 7000 5970 Rev A page 52 of 396 2 Tap the Power Button ...
Страница 54: ...USER MANUAL RSS 1000 CVSI 7000 5970 Rev A page 54 of 396 REBOOTING SOFTWARE 1 Tap the Logout button ...
Страница 55: ...USER MANUAL RSS 1000 CVSI 7000 5970 Rev A page 55 of 396 2 Tap the Power Button ...
Страница 124: ...USER MANUAL RSS 1000 CVSI 7000 5970 Rev A page 124 of 396 5 Tap on the Logout button 6 Tap the Power button ...
Страница 128: ...USER MANUAL RSS 1000 CVSI 7000 5970 Rev A page 128 of 396 5 Tap on the Logout button 6 Tap the Power button ...
Страница 220: ...USER MANUAL RSS 1000 CVSI 7000 5970 Rev A page 220 of 396 5 Array Path Pattern 5 1 Vertical Zig Zag 1 4 7 2 5 8 3 6 9 ...
Страница 221: ...USER MANUAL RSS 1000 CVSI 7000 5970 Rev A page 221 of 396 5 2 Horizontal Zig Zag 1 2 3 4 5 6 7 8 9 ...
Страница 222: ...USER MANUAL RSS 1000 CVSI 7000 5970 Rev A page 222 of 396 5 3 Vertical Square Zig Zag 1 6 7 2 5 8 3 4 9 ...
Страница 223: ...USER MANUAL RSS 1000 CVSI 7000 5970 Rev A page 223 of 396 5 4 Horizontal Square Zig Zag 1 2 3 6 5 4 7 8 9 ...
Страница 224: ...USER MANUAL RSS 1000 CVSI 7000 5970 Rev A page 224 of 396 5 5 Spiral 1 2 3 8 9 4 7 6 5 ...