USER MANUAL, RSS-1000-CVSI
7000-5970
Rev.
A
page
345
of
396
7. Tap on the yellow box to the right of the Solder Point Clean Frequency icon
to enter the
number of joints the unit will solder before heading to the cleaning zone.
8. Tap on the yellow box to the right of the Solder Point Clean Frequency icon
to enter the
number of joints the unit will solder before heading to the cleaning zone.
9. Tap on the yellow box to the left of the Solder Retract Length icon
to enter the length (in
millimeters) of solder that is to be retracted into the solder tube assembly during the cleaning zone
9.1. This information will only be known once the solder feeder tube assembly is adjusted in the
desired location.
9.2. With the iron hot, solder should be fed until the solder wire contacts the tip.
9.3. After contact is made, use a pair of calipers to measure the length from the solder feeder tube
to the tip of the un-melted solder wire.
9.4. Enter measured value in the yellow box to the left of the of the Solder Retract Length icon.
10. Tap the Confirmation button
to accept all settings and proceed with the implementation of
the Tip Cleaning Profile.
10.1.
Tap the Cancel button
to make any further changes or to abort any changes
altogether.
Tip Cleaning Profile Implemented!
Содержание RSS-1000-CVSI
Страница 21: ...USER MANUAL RSS 1000 CVSI 7000 5970 Rev A page 21 of 396 ROBOT BASE CONNECTIONS N ...
Страница 51: ...USER MANUAL RSS 1000 CVSI 7000 5970 Rev A page 51 of 396 POWERING OFF THE UNIT 1 Tap the Logout button ...
Страница 52: ...USER MANUAL RSS 1000 CVSI 7000 5970 Rev A page 52 of 396 2 Tap the Power Button ...
Страница 54: ...USER MANUAL RSS 1000 CVSI 7000 5970 Rev A page 54 of 396 REBOOTING SOFTWARE 1 Tap the Logout button ...
Страница 55: ...USER MANUAL RSS 1000 CVSI 7000 5970 Rev A page 55 of 396 2 Tap the Power Button ...
Страница 124: ...USER MANUAL RSS 1000 CVSI 7000 5970 Rev A page 124 of 396 5 Tap on the Logout button 6 Tap the Power button ...
Страница 128: ...USER MANUAL RSS 1000 CVSI 7000 5970 Rev A page 128 of 396 5 Tap on the Logout button 6 Tap the Power button ...
Страница 220: ...USER MANUAL RSS 1000 CVSI 7000 5970 Rev A page 220 of 396 5 Array Path Pattern 5 1 Vertical Zig Zag 1 4 7 2 5 8 3 6 9 ...
Страница 221: ...USER MANUAL RSS 1000 CVSI 7000 5970 Rev A page 221 of 396 5 2 Horizontal Zig Zag 1 2 3 4 5 6 7 8 9 ...
Страница 222: ...USER MANUAL RSS 1000 CVSI 7000 5970 Rev A page 222 of 396 5 3 Vertical Square Zig Zag 1 6 7 2 5 8 3 4 9 ...
Страница 223: ...USER MANUAL RSS 1000 CVSI 7000 5970 Rev A page 223 of 396 5 4 Horizontal Square Zig Zag 1 2 3 6 5 4 7 8 9 ...
Страница 224: ...USER MANUAL RSS 1000 CVSI 7000 5970 Rev A page 224 of 396 5 5 Spiral 1 2 3 8 9 4 7 6 5 ...