background image

971

 

  LONER

®

high performance

Temperature Controlled
Soldering Station

SPECIFICATIONS

•  120V, 50/60Hz, 70W, 2.5 lbs. (1.13 kg.)
•  COMPLIES WITH DOD-STD-2000-1B, MIL-STD-

2000A and ESD SPEC. DOD-STD 1868, DOD-
HDBK-263

•  TEMP. RANGE: 400°F - 800°F (205°C - 427°C)
•  TEMP. REGULATION: ±6°F (±3°C)
•  TIP TO GROUND LEAKAGE: < 2MV
•  TIP TO GROUND RESISTANCE: < 2 OHMS
•  UL LISTED

m a d e

in

U S A

Static Safe

1.  Turn on power

 

and set Temperature 

Control  Knob to 400°F. 

2.  Using a clean and well tinned Tip, 

apply a small amount of solder on the 
Tip, just enough to form a bead on top 
of the Tip.

3.  Place the center of the thermocouple 

wire of the 

SDS100

 on top of the bead.

4.  Again, apply a small amount of solder 

on the center of the thermo-couple 
wire, just enough to embed the center.

5.  Adjust LO-Temp. Calibration Pot so the  

Meter will read 400°F.  

6.  Set Temperature Control Knob to 800°F.
7.  Adjust Hi-Temp. Calibration Pot so the 

Meter will read 800°F.

AIR MOVEMENT WILL AFFECT THE TEMPERATURE READING.  
WORK IN AN AREA WHERE THIS IS MINIMAL.

MS412 

Temperature 
Calibration System

SDS100

FX635

TEMPERATURE CALIBRATION

TIP CARE

 

1. Set desired temperature.  Blinking 

Lamp means Tool is regulating.

2. TIN the Tip. (apply solder)
3. Do not rub, bend or reshape the Tip.
4. Always clean the Tip by wiping it 

against the saturated sponge and 
always RE-TIN.

Temp. Control

Hi/Lo Temp. Calibration Pot

Temp. Regulation 

Indicator

Sponge Holder

Power Switch

Loosen RCS71 
Collar by turning 
counter-clockwise 
and pull the Tip 
straight out.

Direct Tip/Heater 

Contact

PD528 

Tool Pod

WARNING: DO NOT HIT OR TAP THE 
TOOL.  HEATER ELEMENT WILL BREAK!!!

To replace Pod, 
press Release Tab 
and slide out Pod. 

Содержание 971 LONER

Страница 1: ...enough to embed the center 5 Adjust LO Temp Calibration Pot so the Meter will read 400 F 6 Set Temperature Control Knob to 800 F 7 Adjust Hi Temp Calibration Pot so the Meter will read 800 F AIR MOVEMENT WILL AFFECT THE TEMPERATURE READING WORK IN AN AREA WHERE THIS IS MINIMAL MS412 Temperature Calibration System SDS100 FX635 TEMPERATURECALIBRATION TIP CARE 1 Set desired temperature Blinking Lamp ...

Страница 2: ...1 a 971 LONER High Performance SOLDERING STATION SPARE PARTS LIST 4 a i h d e f a b c 7 11 5 3 2 13 d c b 9 24 6 20 21 17 17a 16 19 25 23 7 9 15 18 14 10 j g c 22 12 b C PM6 SERVICE 971 PM4 Rev C ...

Страница 3: ...ip 6 18 x 5 8 4 16 SR054 Bottom Weight 1 17 SR252 Power Cord Assy 1 17a SR026 Power Cord only Connectors not included 1 18 SR251 Rubber Foot 4 19 SR226 Strain Relief Block for Tool Cord Tool Cord Assy not included 1 20 SR241 Strain Relief for Power Cord 1 21 SR249 Fuse 250V 1 6 A 5mm x 20 mm 1 22 SR575 Soldering Tool Complete Assembly 1 22a SR579 Handle for Tool 1 22b SR058 Cord Strain Relief 1 22...

Страница 4: ...ip AFTER TIP IS INSTALLED TIGHTEN COLLAR PROPERLY Loosen RCS71 Collar by turning coun ter clockwise and pull the Tip straight out Part No Description a b LT374 Standard Probe 03 0 8 mm 48 12 2 mm LT375 Standard Spade 06 1 5 mm 48 12 2 mm LT376 7 SMD Channel 12 3 0 mm 48 12 2 mn LT392 Extra Long Needle 02 0 5 mm 1 13 28 8 mm LT394 Extra Long Spade 07 2 0 mm 93 23 6 mm LT399 Large Face 17 4 3 mm 49 ...

Отзывы: