- 97 -
U.motion KNX Server Plus, Touch
Installation Manual
For each message, the trigger time is displayed, and the time at which the message has been read. In addition it is possi-
ble to change the status of a message from "READ" to "UNREAD" or from "UNREAD" to "READ" through the correspond-
ing checkbox.
A date-based filter function allows filtering certain messages. Simply enter the start and end dates for the period of inter-
est and update the result using the "UPDATE"-button.
The resulting messages in the lists can then be exported to a CSV file. Filter the the messages of the desired time period
and then export them into CSV-file by using the button "EXPORT AS CSV".
11.7
C
LIENTS AND
P
AGE
J
UMPS
For each device connecting to U.motion KNX Server Plus Touch via browser access (including U.motion KNX Server Plus
Touch itself), an object of the type CLIENT is created within the software and automatically gets the IP address of the
corresponding client device as name. These objects are used from U.motion KNX Server Plus Touch on one hand to make
the same user's simultaneous access possible also from several client devices, and on the other hand offer also some
additional functionality. Remember that U.motion KNX Server Plus Touch supports only 1 standard client (desktop PC /
notebook / MAC), but several mobile devices or U.motion Client Touch 7.
The section "CLIENTS" in the menu "ADVANCED FUNCTIONS" of the administration menu collects these objects, which
are handled autonomously by the system and have their visibility set to “false” in normal case (therefore they are listed in
gray). Of course they can still be selected and it is also possible to access their properties window just like with other
objects:
The properties window of the CLIENT object offers the following parameters:
NAME
Label which identifies the CLIENT device. Normally this will be the IP address, but it
can be modified for an easier recognition of the target device (e.g.: “touch bedroom”)
IP ADDRESS
IP address. Can only be modified on manually created objects.
VOIP NUMBER
A number can be assigned to the CLIENT device, over which it can be called from
another place (like other client devices or eve IP phones). If this parameter is
configured, the button "UPDATE CONF." must be clicked in order to save the changes.
ON U.motion KNX Server Plus Touch ONLY THE CLIENT OBJECT 127.0.0.1 CAN BE
USED, FOR ENABLING U.motion KNX Server Plus Touch ITSELF FOR INTERCOM
COMMUNICATION!