FOCKE MELER GLUING SOLUTIONS
4-32
USE
To write over any writing variable (R/W), you must do the following:
1. Fill out all writing variables with the correct data.
2. Enter the following data in the HOST HEAD and HOST TAIL variables:
HOST_HEAD = 0x1111
HOST_TAIL = 0x2222
3. Enter in the HOST_CMD variable, the following writing command:
HOST_CMD = 0XCA00
Once the variables are written, change the writing command to stop it from
continuing to write.
4. Enter in the HOST_CMD variable, any command NOT to write:
HOST_CMD = 0X0000 (for example)
Profibus interface
Pin
Signal
In/Out
Description
Conenct to
1
n. c.
Not connected
2
n. c.
Not connected
3
PB_B
IO
PROFIBUS B-Line
PB-Interface
4
PB_RTS
O
Request-To-Send
PB-Interface
5
GND_ISO
Ground (isolated)
PB-Interface
6
VCC_ISO
VCC 5V (isolated)
PB-Interface
7
n. c.
Not connected
8
PB_A
IO
PROFIBUS A-Line
PB-Interface
9
n. c.
Not connected
SHIELD
Shield
Housing