MA-5151-ENG
PATTERN CONTROLLER STARBI
USE
4-3
Screen navigation. User menu
The 7 inch touchscreen of the unit shows the main data and contains the user
menu for the custom configuration and use of the unit.
General characteristics
In general, there are several icons and pieces of information that are repeated
throughout the screen navigation, so they will be explained at the beginning
and then not in the next screens.
Navigation icons
Right arrow icon (FORWARD), located in the lower right part of the screen.
Appears when there is a possibility of navigation to a next screen. From the
HOME screen it provides access to the MENU.
Left arrow icon (BACK), located in the lower left part of the screen. This icon
appears on all the menu screens, allowing you to return to the previous
screen.
From any screen you can return to the main screen by clicking on the icon
(HOME) located in the bottom centre of the screen.
Operating anomalies
When the unit detects an anomalous situation, but not enough to switch to
STOPPED mode, the YELLOW LED is activated. The GREEN LED stays on if the
unit is in RUNNING mode.
If the cause of the anomaly disappears, the YELLOW LED turns off and the unit
continues in RUNNING mode.
List of errors and anomalies
BACK
HOME
FORWARD
Type
Text of the alarm
Description
Status of the
unit
Central LED
Error
Alarm in EV 1
Channel 1 not connected
STOPPED
Red
Error
Alarm in EV 2
Channel 2 not connected
STOPPED
Red
Error
Alarm in EV 3
Channel 3 not connected
STOPPED
Red
Error
Alarm in EV 4
Channel 4 not connected
STOPPED
Red
Error
Alarm in EV 5
Channel 5 not connected
STOPPED
Red
Error
Alarm in EV 6
Channel 6 not connected
STOPPED
Red
Error
IOC not responding
Communication failure between boards
STOPPED
Red
Anomaly
-
Low line speed (less than the
programmed value in ‘Minimum speed of
movement’)
RUNNING
Yellow