MA-5151-ENG
PATTERN CONTROLLER STARBI
USE
4-29
HOLDING
Register
Address
Description
MAGNITUDE
MIN
MAX
Read / Write
TYPE
40001
0
Year
number
2018
65535
R / W
Uint16
40002
1
Month
number
1
12
R / W
Uint16
40003
2
Day
number
1
31
R / W
Uint16
40004
3
Hour
number
0
23
R / W
Uint16
40005
4
Minute
number
0
59
R / W
Uint16
40006
5
Second
number
0
59
R / W
Uint16
40007
6
Language
number
0
5
R / W
Uint16
40008
7
Status
number
0
3
R / W
Uint16
40009
8
Available product
number
number
0
100
R
Uint16
40010
9
Selected product
number
0
100
R / W
Uint16
Values:
1 ----- 1: StarBi / 2: Micron Pump / 3: Micron Gear / 4: PS 20 NS / 5:Macro
4 ----- 0: OFF / 1:ON
5 ----- 0: OFF / 1:ON
6 ----- 0: OFF / 1:ON
7 ----- 0: OFF / 1:ON
8 ----- Bit0: FC1 Bit1:FC2 … -> 0x11 = 0001 0001 = FC1 ON and FC5 ON
9 ----- Bit0: C1 Bit1:C2 … -> 0x11 = 0001 0001 = C1 ON and C5 ON
10 ---- 0 to 10V value * 100 : 854= 8,54V
11 ---- 1 to 10V value * 100 : 854= 8,54V
12 ---- 2 to 10V value * 100 : 854= 8,54V
30 ---- Since product was manufactured. If Total product Low =65535 then (High++ and Low=0)
31 ---- Since product was manufactured. If Total product Low =65535 then (High++ and Low=0)
Values:
6 ----- 0:English, 1:Spanish …
7 ----- STATUS: STOPPED (0), READY (1), RUNNING (2), MANUAL (3).
Modbus connections
DB9 Pin 1 = GND
DB9 Pin 5 = B (D1)
DB9 Pin 9 = A (D0)
2 Outputs
4/6 Outputs
4