“3084 Speed Level™ Sigma Lift” Service and Parts Manual
November 2009
Page 2-17
C
O N T I N U I T Y
C
H E C K S
Figure 2-18:
Button Switch, Momentary
M
OMENTARY
B
UTTON
S
WITCH
• Disconnect wires.
• Connect one probe of ohm meter each terminal.
• With the button in the neutral (open) position there
should be no reading.
• With the button pushed (closed) there should be a low
resistance
Figure 2-19:
Emergency Stop Switch
E
MERGENCY
S
TOP
B
UTTON
• Disconnect wires.
• Connect one probe of ohm meter each terminal.
• With the button PRESSED there should be no reading.
• With the button RESET there should be a low resistance.
Figure 2-20:
Relay Operation
R
ELAY
• With the #85 terminal grounded, apply voltage to
#86 terminal connection.
• Confirm normally closed (#87A) contacts are
opening. Continuity with #30 will be broken.
• Confirm normally open (#87) contacts are clos-
ing. Continuity with #30 will be made.
Commo
n
No
r
mally Ope
n
Commo
n
No
r
mally Ope
n
ART_2565
1
1A
ART_2566
ART_2330
RELAY DETAIL
(
r
elay e
n
e
r
gized)
85
86
87
87A
30
OPEN
CLO
S
ED
B+
B−