“3084 Speed Level™ Sigma Lift” Service and Parts Manual
November 2009
Page 2-23
G P 4 0 0 C
O N T R O L
M
O D U L E
S
E T U P
7. Press Right Arrow to SETUPS, Press Enter.
• Display reads CHANGE DEFAULTS
8. Press Right Arrow to LOAD SETUPS. Press Enter.
• Display reads CALIBRATE LOAD
9. Press Enter.
• Display reads PLATFORM DOWN? Verify that platform is fully lowered.
10. Press Enter.
• Display reads PLATFORM LOADED? Verify that rated load is in platform.
11. Press Enter.
• Display reads PLEASE LIFT.
12. Hold lower controls switch in the up position until machine is fully elevated, then
release switch.
• Display reads PLEASE LOWER.
13. Hold switch in down position until platform is in the fully lowered position. Release
switch.
• Display reads PLATFORM LOADED?
14. Ensure that the rated load is distributed evenly in the platform, then press Enter.
• Display reads PLEASE LIFT.
15. Hold lower controls switch in the up position until machine is fully elevated, then
release switch.
• Display reads TOTAL DATA #XX, then PLEASE LOWER.
NOTE:
The platform will rise incrementally during this phase on the calibration. Do not release the switch until fully
elevated.
16. Hold switch in down position until platform is in the fully lowered position.
NOTE:
The platform will lower incrementally during this phase on the calibration. Do not release the switch until
fully lowered.
17. Release switch.
• Display reads TOTAL DATA #XX, then PLATFORM EMPTY?
18. Remove the load from the platform.
NOTE:
If you must switch to platform controls to move the machine, steps 1.] through 7.] must be repeated. Steps
12.] through 20.] will generate the REDO prompt. Answer NO. If machine was not moved, proceed to step 22.].
19. Press Enter.
• Display reads PLEASE LIFT.
20. Hold lower controls switch in the up position until machine is fully elevated, then
release switch.
• Display reads TOTAL DATA #XX, then PLEASE LOWER.
21. Hold switch in down position until platform is in the fully lowered position.
• Display reads TOTAL DATA #XX, then BUILDING TABLES, then CALDATE mm/dd/yy.
22. Enter current date using Up, Down and Right Arrows.
• Display reads FINISHED.
23. Disconnect EZ-Cal.
The Platform Overload Sensing System is now calibrated.
Содержание Speed Level 2684 ES
Страница 52: ...3084 Speed Level Sigma Lift Service and Parts Manual October 2009 Page 1 32 GENERATOR OPTION 3084RT NOTES...
Страница 104: ...3084 Speed Level Sigma Lift Service and Parts Manual November 2009 Page 3 20 ENGINE MAINTENANCE NOTES...
Страница 142: ...3084 Speed Level Sigma Lift Service and Parts Manual November 2009 Page 4a 38 TROUBLESHOOTING 3084RT MODELS NOTES...